4gpoCAN is a four channel CAN output module. When on the same CAN bus as an ECM emissions module (i.e. LambdaCANp, NOxCAN*, NH3CAN, COCO2CAN, pmCAN, baroCAN), 4gpoCAN can be used to generate 0 to 5V or 4 to 20mA outputs for the module’s parameters. ECM’s Configuration Software is used to set up the module (Baud Rate, Node ID, Outputs). Each of the four channels can be a 0 to 5V or a 4 to 20mA output and each output can be individually assigned to a unique Source Module and Data Parameter from that module. Output resolution is 0.015% (>12 bits) and is updated every 10ms. Electrical connections via BNC connectors. The gray connector is a Deutsch P/N: DTM06-12A. The terminal lock is P/N: WM12S. Terminals are P/N: 0462-201-2031 and are crimped using tool P/N: HDT-48-00.
Recommended module power is 12V to 24V (28V Maximum). Current draw is 160mA @ 24V.
Module (Electronics) Temperature Range: -40 to 85 ⁰C
Enclosure is 145mm x 120mm x 60mm and IP67.
Important Notes:
- All output grounds connected to each other but not to either power ground or CAN ground.
- Use Configuration Tool Version 4.47.1 or later. Download from www.ecm-co.com