4gpoCAN Kit

(CAN to 0 to 5V and 4 to 20mA Output Conversion)

4gpoCAN is a four channel CAN output module.  When on the same CAN bus as an ECM emissions module (i.e.  LambdaCANp, NOxCAN*, NH3CAN, COCO2CAN, pmCAN, baroCAN), 4gpoCAN can be used to generate 0 to 5V or 4 to 20mA outputs for the module’s parameters.  ECM’s Configuration Software is used to set up the module (Baud Rate, Node ID, Outputs).  Each of the four channels can be a 0 to 5V or a 4 to 20mA output and each output can be individually assigned to a unique Source Module and Data Parameter from that module.  Output resolution is 0.015% (>12 bits) and is updated every 10ms.  Electrical connections via BNC connectors.  The gray connector is a Deutsch P/N: DTM06-12A.  The terminal lock is P/N: WM12S.  Terminals are P/N: 0462-201-2031 and are crimped using tool P/N: HDT-48-00.

Recommended module power is 12V to 24V (28V Maximum).  Current draw is 160mA @ 24V.
Module (Electronics) Temperature Range: -40 to 85 ⁰C

Enclosure is 145mm x 120mm x 60mm and IP67.

Important Notes:

  1. All output grounds connected to each other but not to either power ground or CAN ground.
  2. Use Configuration Tool Version 4.47.1 or later.  Download from www.ecm-co.com

Included Kit Components

Filters Sort results

Accessories

Filters Sort results

Downloads

4gpoCAN Manual (Ver. 2022-12-28, 234 KB)
ECM Configuration Tool (Ver. 4.48.20, 30 MB)