Home > Air-Fuel Ratio, Oxygen, & Lambda Modules > LambdaCANp
LambdaCANp
Description:
Zoom
123456789
ECM's LambdaCANp Module is a powerful, "next-generation" wideband Lambda (and AFR, O2) measurement module with a CAN interface. In addition to providing outstanding measurement range and accuracy, LambdaCANp addresses the two principle sources of error with wideband sensor use: sensor aging and pressure sensitivity. All wideband sensors and pressure sensors supplied are factory-calibrated and this calibration is stored in a memory chip in the sensor's connector. For best accuracy over the life of the wideband sensor, calibration can be quickly performed using ambient air. This recalibration is stored in the memory chip and stays with the sensor. Sensors can be tested and recalibrated in a central location and distributed to users, ensuring consistent results throughout a large test facility. Pressure compensation (P-COMP™) improves accuracy at non-stoichiometric (i.e. λ ≠ 1) and non-atmospheric (i.e. P ≠ 101 kPa) conditions. For example, a pressure increase of only 34 kPa will cause an error of 0.58 λ at λ = 3. Pressure compensation eliminates this error and enables innovative applications such as %O2 measurements in intake manifolds. Pressure data is available on the CAN bus.

LambdaCANp will work with all NTK and Bosch-type wideband sensors. It is programmable for all fuel types (H:C, O:C, N:C ratios and H2). LambdaCANp outputs λ, AFR, %O2, pressure, and all sensor parameters including pumping current, resistance, and sensor age factor.
Specifications:
Inputs:1 Wideband Lambda Sensor, 1 Pressure Sensor (optional)
Ranges:λ 0.4 to 25
AFR 6 to 364
F/A 0.003 to 0.167
φ 0.04 to 2.5
O2 0 to 25%
Pressure (optional) 0 to 517 kPa (0 to 75 psia)
Accuracies:λ, AFR, φ ± 0.6% (at stoichiometric), ± 0.9% (average, elsewhere)
%O2 ± 0.1% (absolute)
Pressure (optional) ± 0.7 kPa (± 0.10 psia)
Response Time:Less than 150 ms
Fuel Type:Programmable H:C, O:C, and N:C ratios, and H2
CAN:High Speed according to ISO 11898
Configuration:Via CAN Bus with Configuration Software. Programmable Node ID.
Module:145mm x 120mm x 40mm, Environmentally Sealed
Environmental: Electronics -55 to +125°C, IP67
Sensor 850°C (maximum continuous)
Sensor Cable:0.25m (sensors), +1m (standard), +2m (optional)
Power:8 to 28 VDC, AC/DC (optional)
Sensor Mounting:18mm x 1.5mm thread (wideband), 1/4" NPT (pressure)
Jump to Optional Kits and Parts
Related Downloads:
LambdaCANp Brochure (11-12-2014, 234KB)
Aluminum Block Brochure (27KB)
Exhaust Probe Brochure (104KB)
Vboost Power Supply Brochure (165KB)
ETAS INCA Setup Guide (1052KB)
ATI VISION Setup Guide (504KB)
ECM CAN Configuration Tool (v4.47.5, 18440KB)
Firmware Update Procedure for Modules (225KB)
Ordering Information, Complete Kit P/N: LambdaCANp
The complete kit includes the following parts:
ItemDescriptionP/NQtyPhoto
1.LambdaCANp Module02-081
2a.NTK 6mA O2 Sensor, or05-011
2b.Bosch LSU4.2 O2 Sensor, or05-021
2c.Bosch LSU4.9 O2 Sensor, or05-031
2d.NTK 4mA O2 Sensor05-041
3.Eurofast 12mm Cable, 2m09-021
4.Flexi-Eurofast Cable, 0.3m09-041
5.Eurofast "T" Connector09-051
6.Eurofast Termination Resistor09-061
7.Lambda/NOx/NH3 Cable, 1m10-021
8.DC Power Cable, DB9F, Banana Plugs11-021
9.18mm x 1.5mm Mild Steel Boss and Stainless Steel Plug12-021
10.5200 Series Manuals & Configuration Software CD
This PC-based software allows configuration of CAN communication, calibration of sensors, and data logging. Requires Kvaser, Vector, or Peak USB-to-CAN adapter. (Available from ECM, see P/N 13-02 below)
13-011


Optional Kits and Parts:

For pressure compensation, these additional items are included:
ItemDescriptionP/NQtyPhoto
1a.Pressure, Type KP, 0-75 psia, 1/4" NPT (USA), or07-101
1b.Pressure, Type KP, 0-517 kPa, 6mm (Metric)07-111
2.Module Y Cable (For LambdaCANp only)10-341
3.Pressure Cable (8-terminal), 1m10-351
4a.Pressure Line Assembly, 1/4" NPT Tubing/Hose/Fittings, 28" Length (USA), or12-081
4b.Pressure Line Assembly, 6mm Tubing/Hose/Fittings, 711mm Length (Metric)12-111

Accessories:
ItemDescriptionP/NQtyPhoto
1.CAN-to-USB Adapter13-021
2.AC/DC Power Supply w/ CAN Tap, Universal, 24VDC 4.2A
(Requires P/N 11-17 for use with CAN-to-USB adapter)
04-011
3.Deutsch DTM3M to DB9F11-171
4.DC Power Cable, DB9F, Spades11-011
5.DC Power Cable, DB9F, Banana Plugs, 1m11-361
6.Vboost Power Supply (Boosts supply voltage to avoid dropout situations)04-021
7.AC/DC Power Supply, 120VAC In, 15VDC 15A Out, 4.5" x 6" 10", 13lbm
(Up to 4 Modules and 2 Display Heads)
04-041
8.AC/DC Power Supply, 120VAC In, 24VDC 15A Out, 7.5" x 7.0" x 2.5", 4lbm
(Up to 8 Modules and 4 Display Heads)
04-031
9.AC/DC Power Supply, 120VAC In, 15VDC 60A Out, 6.75" x 10.5" x 11.5", 33lbm
(Up to 16 Modules and 8 Display Heads)
04-051
10.Eurofast 12mm Cable, 10m09-03/101
11.Lambda/NOx/NH3 Cable, 2m10-031
12.Lambda/NOx/NH3 Cable, 3m10-371
13.Pressure Cable (8-terminal), 2m10-361
14.Pressure Cable (8-terminal), 3m10-381
15.Lambda Sensor Extension Cable with Midpoint Lemo Connectors (Controller Side)10-42A1
16.Lambda Sensor Extension Cable with Midpoint Lemo Connectors (Sensor Side)10-42B1
17.Eurofast Hub Block, 8-channel09-081
18.Termination Resistor for Hub Block09-091
19.2m Hub Power/Eurofast Harness11-101
20.1/4" UNC Module Stacking Standoff
(Use to mount and stack ECM CAN modules. One kit mounts/stacks two
modules. Each additional kit mounts/stacks an additional module.)
12-251
21.dashCAN+DASHP1
22.dashCAN2DASH21
23.dashCANDASH1
24.Aluminum Mounting Plate for 8-Ch Block and Modules (16" x 10" x 0.16")12-421
25.19" Rackmount Panel (holds up to 4 display heads or 4 dashCANs)12-011
26.18mm x 1.5mm Mild Steel Boss and Stainless Steel Plug12-021
27.1/4" NPT Mild Steel Boss and Brass Plug (USA)12-051
28.1/4" ISO Mild Steel Boss and Brass Plug (Metric)12-121
29.Aluminum Remote Sensor Mounting Block (18mm x 1.5mm, 5 x 1/4" NPT)12-181
30.Individual Cylinder Exhaust Probe (18mm x 1.5mm) (USA)12-191
31.Individual Cylinder Exhaust Probe (18mm x 1.5mm) (Metric)12-201