ECM’s FastTemp™ thermocouple module outputs ultra-high bandwidth temperature measurements using standard K-Type (Chromel Alumel) grounded thermocouple probes. Measurements that once required a 0.005″ (0.13mm) diameter exposed-bead thermocouple can now be performed using a 1/16″ (1.5mm) shielded (i.e. more rugged) thermocouple. The speed increase is made possible by ECM’s proprietary active-drive thermocouple circuitry. With FastTemp™, fast dynamic temperature information hidden by conventional thermocouple amplifiers now becomes available for use. FastTemp™ is especially suited for temperature measurements in the exhaust of engines for engine control, engine durability, turbocharger, aftertreatment, and exhaust system development.
General
Response Time |
Fast Output: Less than 50 ms (10 to 90%) Standard Output: Dependent on probe used |
Power |
6 to 35 VDC, 200mW typical 500V galvanic isolation from sensor input and outputs LED power status indicator |
Dimensions |
152mm x 70mm x 30mm (6" x 2.75" x 1.2"), 360gm (12.7oz) Two 1/5" (5mm) holes from top, Two 10-32 (M5 x 0.8) threaded holes on back Sensor Cable 2m, Power Cable 2m. |
Operating Temperature | For module (electronics): -55 to +125°C, 100% humidity, environmentally sealed, IP67 |
Ranges & Accuracies
Temperature |
-60 to 1370°C (-76 to 2498°F) ± 1°C RTI (relative to input) ± 10mV RTO (relative to output) Internal cold junction compensation |
Outputs
Analog |
5mV/ °C for Fast and Standard signals Less than 500Ω output impedance 200V Isolation from sensor input to outputs 2 Female BNC connectors |
Included Kit Components
MPN | Description | Quantity | |
---|---|---|---|
12-30S |
1 |
||
FT-01 |
1 |
||
FT-02 |
1 |
||
FT-03 |
1 |
||
FT-04 |
1 |
||
FT-05 |
1 |
Accessories
Note: To connect multiple FastTemp modules, you will need P/N 09-04, 09-05, and FT-11 per module.
MPN | Description | Quantity | |
---|---|---|---|
04-01 |
1 |
||
FT-06 |
1 |
||
FT-07 |
1 |
||
FT-08 |
1 |
||
FT-09 |
1 |
||
FT-10 |
1 |
||
FT-11 |
1 |
||
FT-12 |
1 |